GLUCOBAND & GLUCOWATCH

GLUCOBAND

GLUCOBAND


The Glucoband is a compact electronic scanning device that utilizes a bio-electromagnetic resonance phenomenon to non-invasively measure blood glucose levels in the human body, and to continuously monitor the blood glucose level. The device is based on the technology called Bio-Electric Impedance Spectroscopy (BEIS).

A wrist-watch-like Glucoband, with fully integrated LCD screen, electronic circuits, integrated electrodes, battery and adjustable wrist-band, is placed on the person's wrist. The initial measurement process takes only a few minutes, however, in the monitoring mode, measurements can be continuous and only the frequency of measurements must be determined. The Glucoband targets diabetics who are measuring their own blood glucose, and medical personnel who are using blood glucose measuring and monitoring devices in clinics, hospitals and other point-of-care facilities. The measurements meet FDA requirements for accuracy and correlation.

The design of the Glucoband is such that it may be used as a regular wrist-watch or be used as a blood glucose measurement device, at the discretion of the wearer.In the Continuous Monitoring mode, Glucoband can be set to alert upon surpassing a lowest and/or highest preset value.

Glucoband worn on the wrist like regular wristwatch would allow people with diabetes to continuously and non-invasively monitor their blood glucose levels without the pain and inconvenience of multiple fingerstick blood tests or implanting a sensor. Prototypes of the device have shown the capability of providing readings once in 6 minutes.

Continuous glucose monitoring has become an important component of diabetes management for both children and adults.Blood glucose levels are a measure of an individual's health status. Because people with diabetes cannot properly metabolize glucose, they typically monitor their glucose levels by frequently pricking their fingertips to draw the drop of blood necessary for conventional glucose monitoring. The estimated worldwide market for glucose testing is $5.5 billion with an annual growth rate of 15 to 18 percent.


GLUCOWATCH

The Cygnus GLUCOWATCH wrist monitor uses a low electric current to pull glucose through the skin. The system, which employs a disposable sensor pad to collect and measure the glucose sample, provides automatic glucose readings up to three times an hour for as long as twelve hours at a time.

GLUCOWATCH
(CYGNUS GLUCOWATCH)

Cygnus GLUCOWATCH G2 BIOGRAPHER, a special version of the GLUCOWATCH is designed for younger diabetic patients aged 7 to 17. It gained FDA approval in May 2005.

CYGNUS GLUCOWATCH G2 BIOGRAPHER


Reference : CALISTOMEDICAL

Monday, 13 August 2007

Blood glucose monitoring

BLOOD IN GLUCOMETER STRIP

Blood glucose monitoring is a way of testing how much glucose is in the blood (glycemia).

BLOOD PLACEMENT IN BLOOD GLUCOSE METER

i.)This is important in the care of diabetes mellitus. Most people with Type 2 diabetes need to test at least once per day (usually before breakfast) to assess the effectiveness of their diet and exercise for controlling their blood glucose levels. Many people with Type 2 are using an oral medication to combat their insulin resistance, and must test their blood glucose before and after breakfast to assess the effectiveness of their dosage.

BLOOD GLUCOSE MONITOR

ii.)All people who need to inject insulin, both for Type 1 diabetes and Type 2, need also to test their blood sugar more often (3 to 10 times per day) to assess the effectiveness of their prior insulin dose and to calculate their next insulin dose.

DIABETES MELLITUS TYPE 1

PANCREAS LOCATION

Diabetes mellitus type 1 (Type 1 diabetes, Type I diabetes, T1D, IDDM) is a form of diabetes mellitus. Type 1 diabetes is an autoimmune disease that results in the permanent destruction of insulin producing beta cells of the pancreas.

PANCREAS

Type 1 is lethal unless treatment with exogenous insulin via injections replaces the missing hormone.

INSULIN & PANCREAS

IDDM TYPE1 DIABETES MELLITUS

DIABETES MELLITUS TYPE 2

'HYPERGLYCEMIA

TYPE2 DIABETES

Diabetes mellitus type 2 (formerly called diabetes mellitus type II, non insulin-dependent diabetes (NIDDM), obesity related diabetes, or adult-onset diabetes) is a metabolic disorder that is primarily characterized by insulin resistance, relative insulin deficiency, and hyperglycemia.

NIDDM TYPE2 DIABETES MELLITUS

It is often managed by engaging in exercise and modifying one's diet.

DIABETIC EXERCISES

It is rapidly increasing in the developed world, and there is some evidence that this pattern will be followed in much of the rest of the world in coming years.

Improved technology for measuring blood glucose is rapidly changing the standards of care for all diabetic people. There are several methods of blood glucose testing currently available.

CHEMICAL TEST STRIPS

Chemical test strips are a low cost method for monitoring blood glucose. A fairly large drop of blood, usually taken from the fingertip, is placed on a chemically prepared strip, called a blood glucose testing strip.The strip chemistry will cause it to change color according to the amount of glucose is in the blood.

BLOOD GLUCOSE STRIPS

One can tell if their level of blood glucose is low, high, or normal by comparing the color on the end of the strip to a color chart that is printed on the side of the test strip container.

BLOOD GLUCOSE STRIP COLOR CHART

BLOOD GLUCOSE STRIP COLOR CHART-2

GLUCOSE TEST STRIP COLOR

These are recommended only for people who are occasionally monitoring their blood glucose level (prediabetic or type 2) and are not using insulin.

The Betachek Diabetes Test Strips


BLOOD GLUCOSE METERS

BLOOD GLUCOSE METER OPERATION

A blood glucose meter is an electronic device for measuring the blood glucose level. A relatively small drop of blood is placed on a disposable test strip which interfaces with a digital meter. Within several seconds, the level of blood glucose will be shown on the digital display.

BLOOD FOR GLUCOSE MONITOR

DIGITAL BLOOD GLUCOSE METER DISPLAY

BLOOD GLUCOSE METER ACCESSORIES

While more expensive, blood glucose meters seem a breakthrough in diabetes self care. As the drops of blood needed for the meter become smaller, the pain associated with testing is reduced and the compliance of diabetic people to their testing regimens is improved. Although the cost of using blood glucose meters seems high, it is believed to be a cost benefit relative to the avoided medical costs of the complications of diabetes.

A recent and welcome advance is the use of small blood drops for blood glucose testing from other places than the finger tips.



This alternate site testing uses the same test strips and meter, is practically pain free, and gives the real estate on the finger tips a needed break if they become sore.

ALTERNATE SITE GLUCOSE TESTING
(ALTERNATE SITE GLUCOSE TEST- BLOOD TAKEN FROM FOREARM INSTEAD OF FINGER)


CONTINUOUS BLOOD GLUCOSE MONITORING (AMBULATORY)

A continuous blood glucose monitor determines blood glucose levels on a continuous basis (every few minutes). A typical system consists of:

i.)a disposable glucose sensor placed just under the skin, which is worn for a few days until replacement,

CONTINUOUS GLUCOSE SENSOR
(A-INSULIN PUMP, B-CANNULA, C-TINY GLUCOSE SENSOR, D-REAL TIME TRANSMITTER)

ii.)a link from the sensor to a non-implanted transmitter which communicates to a radio receiver,

CONTINUOUS BLOOD GLUCOSE MONITOR

iii.)an electronic receiver worn like a pager (or insulin pump) that displays blood glucose levels on a practically continuous manner, as well as monitors rising and falling trends in glycemic excursions.

INSULIN PUMP

CONTINUOUS BLLOD GLUCOSE MONITOR

Continuous blood glucose monitors measure the glucose level of interstitial fluid. Disadvantages compared to traditional blood glucose monitoring are:

i.)continuous systems must be calibrated with a traditional blood glucose measurement (using current technology) and therefore do not yet fully replace "fingerstick" measurements.
ii.)glucose levels in interstitial fluid lag temporally behind behind blood glucose values.

Patients therefore require traditional fingerstick measurements for calibration (typically twice per day) and are often advised to use fingerstick measurements to confirm hypo- or hyperglycemia before taking corrective action.

The lag time discussed above has been reported to be about 5 minutes.Anecdotally, some users of the various systems report lag times of up to 10-15 minutes. This lag time is insignificant when blood sugar levels are relatively consistent. However, blood sugar levels, when changing rapidly, may read in the normal range on a CGM system while in reality the patient is already experiencing symptoms of an out-of-range blood glucose value and may require treatment. Patients using CGM are therefore advised to consider both the absolute value of the blood glucose level given by the system as well as any trend in the blood glucose levels. For example, a patient using CGM with a blood glucose of 100 mg/dl on their CGM system might take no action if their blood glucose has been consistent for several readings, while a patient with the same blood glucose level but whose blood glucose has been dropping steeply in a short period of time might be advised to perform a fingerstick test to check for hypoglycemia.

Continuous monitoring allows examination of how the blood glucose level reacts to insulin, exercise, food, and other factors. The additional data can be useful for setting correct insulin dosing ratios for food intake and correction of hyperglycemia. Monitoring during periods when blood glucose levels are not typically checked (e.g. overnight) can help to identify problems in insulin dosing (such as basal levels for insulin pump users or long-acting insulin levels for patients taking injections). Monitors may also be equipped with alarms to alert patients of hyperglycemia or hypoglycemia so that a patient can take corrective action(s) (after fingerstick testing, if necessary) even in cases where they do not feel symptoms of either condition. While the technology has its limitations, studies have demonstrated that patients with continuous sensors experience less hyperglycemia and also reduce their glycated hemoglobin levels.

Currently, continuous blood glucose monitoring is not automatically covered by health insurance in the United States in the same way that most other diabetic supplies are covered (e.g. standard glucose testing supplies, insulin, and even insulin pumps). However, an increasing number of insurance companies do cover continuous glucose monitoring supplies (both the receiver and disposable sensors) on a case-by-case basis if the patient and doctor show a specific need. The lack of insurance coverage is exacerbated by the fact that disposable sensors must be frequently replaced (sensors by Dexcom and Minimed have been FDA approved for 7- and 3-day use, respectively, though some patients wear sensors for longer than the recommended period) and the receiving meters likewise have finite lifetimes (less than 2 years and as little as 6 months). This is one factor in the slow uptake in the use of sensors that have been marketed in the United States.

Some current and future continuous glucose monitoring products include:
i.)The Freestyle Navigator
ii.)Minimed Paradigm insulin pump plus a continuous sensor
iii.)The Guardian by Minimed
iv.)Dexcom STS
v.)GlucoDay S

See this summary by a diabetes support group for a review of CBGM products, performance, and features.

This technology is an important component in the effort to develop a closed-loop system connecting real-time automatic control of an insulin pump based on immediate blood glucose data from the sensor. One important goal is to develop an algorithm for automatic control, by which the system would function as an artificial pancreas. Although sensor reliability is more than adequate to improve outcomes for patients when used in an "open-loop" setting where the patient makes judgments about delivery of insulin, it is clearly not ready to be used as part of a closed loop system. FDA had approved the technology for use only in combination with fingerstick testing, and patients are expected to make judgments about treatment only after taking a fingerstick test. Therefore it is overly optimistic to think that these devices will be part of a closed loop system in the near future.

GLUCOSE SENSING BIOIMPLANTS

Longer term solutions to continuous monitoring, not yet available but under development, use a long-lasting bio-implant. These systems promise to ease the burden of blood glucose monitoring for their users, but at the trade off of a minor surgical implantation of the sensor that lasts from one year to more than five years depending on the product selected.

Products under development include:
i.)The SMSI Glucose Sensor
ii.)The Animas Glucose Sensor
iii.)Implanted Glucose Bio-sensor
iv.)The Dexcom LTS (long term system)


NON INVASIVE BLOOD GLUCOSE MONITORING TECHNOLOGY

Some new technologies to monitor blood glucose levels will not require access to blood to read the glucose level. Non-invasive technologies include near IR detection, ultrasound and dielectric spectroscopy. These will free the person with diabetes from finger sticks to supply the drop of blood for blood glucose analysis.

NON INVASIVE GLUCOSE MONITOR

Most of the non-invasive methods under development are continuous glucose monitoring methods and offer the advantage of providing additional information to the subject between the conventional finger stick, blood glucose measurements and over time periods where no finger stick measurements are available (i.e. while the subject is sleeping).

NON-INVASIVE GLUCOSE TESTING

Products under development include:
i.)Fovioptics retinal glucose analyzer
ii.)Inlight Solutions, NIR glucose sensor
iii.)NIR Diagnostics, NIR glucose sensor
iv.)Sinsys Medical GTS
v.)Solianis Monitoring AG

VARIOUS MODELS OF MODERN GLUCOMETER

PRESTIGEX GLUCOMETER

PRESTIGE GLUCOMETERS

ACCUCHECK GLUCOMETER

COMBINED BP & GLUCOMETER
(COMBINED DIGITAL BP MONITOR & GLUCOMETER")


ALTERNATE SITE TESTING GLUCOMETER
(ALTERNATE SITE TESTING GLUCOMETER)

SYMPTOMS,TESTS & ADVICE FOR DIABETIC PATIENTS

1.)
DIABETIC PATIENTS SYMPTOMS

2.)HYPERGLYCEMIA(HIGH BLOOD GLUCOSE) & HYPOGLYCEMIA (LOW BLOOD GLUCOSE) SYMPTOMS

HYPERGLYCEMIA
(HYPERGLYCEMIA)

LOW BLOOD SUGAR SYMPTOMS

 DIABETIC PATIENT FOOD
This method of treating low blood sugars is called the 15:15 rule. Eat 15 grams of carbohydrate and wait 15 minutes

3.)Fasting plasma glucose test -- this is the simplest and fastest way to measure blood glucose and diagnose diabetes. Fasting means that you have had nothing to eat or drink (except water) for 8 to 12 hours before the test. You are diagnosed with diabetes if your blood glucose level is 126 mg/dl or greater on two separate tests.

FASTING PLASMA GLUCOSE TEST

4.)Oral glucose tolerance test -- your blood glucose is tested two hours after drinking 75 grams of glucose. You are diagnosed with diabetes if your blood glucose level is 200 mg/dl or greater.

ORAL GLUCOSE TEST

ORAL GLUCOSE TEST2

5.)A person with type 2 diabetes can use exercise to help control their blood sugar levels and provide energy their muscles need to function throughout the day. By maintaining a healthy diet and sufficient exercise, a person with type 2 diabetes may be able to keep their blood sugar in the normal non-diabetic range without medication.

EXERCISE GLUCOSE
(BEFORE & AFTER EXERCISES)

6.)RISKS OF DIABETES
RISKS OF DIABETES

HIGH INSULIN

Sunday, 12 August 2007

AMBULATORY BLOOD PRESSURE MONITOR

Ambulatory blood pressure monitoring (ABPM) measures blood pressure at regular intervals throughout the day and night. It is believed to be able to reduce the white coat hypertension effect.

BLOOD PRESSURE & HYPERTENSION

BLOOD PRESSURE

Blood pressure is the force that pushes blood through the blood vessels in your body. In people who have high blood pressure, blood is pushed through the blood vessels with greater force than normal. Another word for high blood pressure is "hypertension."

HYPERTENSION SYSTOLE 140 & DIASTOLE 90+

HIGH BP SILENT KILLER

CAUSES OF HIGH BLOOD PRESSURE

1.)A diet high in fat and cholesterol
2.)Not exercising regularly or not exercising hard enough
3.)Being overweight
4.)A family history of high blood pressure
5.)Tobacco use
6.)Stress
7.)Some birth control medicines
8.)Kidney and hormone problems




SYSTOLE & DIASTOLE

SYSTOLE & DIASTOLE IN HEART

Blood pressure is recorded as two numbers separated by a slash, like 120/80. The first number is the systolic (say: "sis-tol-ik") pressure; it is the force when the heart pumps. The second number is the diastolic (say: "die-uh-stol-ik") pressure; it is the force when the heart relaxes between beats.

SYSTOLE, DIASTOLE


SYSTOLIC & DIASTOLIC READINGS

Knowing both of your blood pressure readings can help your doctor tell if you have high blood pressure. Your doctor will want you to keep your usual blood pressure lower than 140/90. If you have diabetes, your doctor will want you to keep your blood pressure lower than 130/85.

BP

NORMAL,HIGH BP VALUES

HEART BP CHART



EFFECTS OF HIGH BP ON BODY PARTS

High blood pressure can damage many parts of the body. If patient has high blood pressure, he/she has a higher risk for stroke, heart disease, heart attacks and kidney failure. Control of the blood pressure can reduce these risks.

HYPERTENSIVE HEART

EFFECTS OF HIGH BP ON BODY PARTS-3

EFFECTS OF HIGH BP ON BODY PARTS-2

EFFECTS OF HIGH BP ON BODY PARTS-1


HEART,HIGH BP DEATH




ASSESSMENT & DIAGNOSIS OF HYPERTENSIVE PATIENTS


(CLICK IMAGE TO ENLARGE)


AMBULATORY BP MONITOR

AMBULATORY BP MONITOR, ABPM

It is a small machine, about the size of a portable radio. The Patient will wear it on a belt. The blood pressure cuff on the monitor can be worn under his/her clothes without anyone seeing it. The picture to thebelow shows a person wearing an ambulatory blood pressure monitor.

AMBULATORY BP

This machine lets doctor find out what patient's blood pressure was every 15 to 30 minutes of a normal day.The information collected by this machine can help patient and doctor see if the blood pressure treatment is working.

The doctor may want patient to use an ambulatory blood pressure monitor for one or more of the following reasons:

1.)If patient has "borderline" high blood pressure
2.)If patient and doctor can't keep your blood pressure under control
3.)If patient has blood pressure problems caused by other medicines
4.)If patient is pregnant and has high blood pressure
5.)If patient has fainting spells

The monitor may help doctor find out if patient is a person who only has high blood pressure when you are at the doctor's office. This is called "white-coat hypertension." If patient has this kind of hypertension, he/she may not need to take medicine.

WORK OF AMBULATORY BP MONITOR ON PATIENT

The small blood pressure cuff that is connected to the monitor will automatically check patient's blood pressure about every 30 minutes, even while he/she is sleeping. The patient also will be asked to keep a diary of his/her day's activities, so doctor will know when he/she was active and when she/she was resting. Some people feel a little sore from the frequent pressure checks. Some people get a rash, but it usually goes away without treatment.

AMBULATORY BP

After 24 hours of monitoring, patient will take the machine and diary to the doctor's office. The blood pressure information is transferred from the monitor to a computer or an analyzer. The computer helps the doctor make sense of the information. Your doctor will review the information with you and decide if your treatment program is working or if you need to make changes to it.

AMBULATORY BP ANALYZER

AMBULATORY 24 HOUR BP GRAPH


ADVICE FOR HIGH BP PATIENTS

CHECK BP FREQUENT

BP CHECKUP

REGULAR MEDIATIONS

EXERCISE DAILY FOR LOWERING BP

HIGH BP MEDICATIONS

BIOMEDICAL BOOKS

Join me on Facebook Follow me on Twitter Subscribe to RSS